FurnaceBlinkCode // RHEEM • RUUD DUAL-TABLE
OEM Control Family: Rheem / Ruud 62-24084 (Table A) & 62-24268 (Table B) • WeatherKing

Rheem & Ruud Furnace Blink Code: 3 Blinks Discrepancy Solved

⚡ Instant OEM Answer (Rheem Table A vs. Table B 3-Blink Rule): Rheem and Ruud use two conflicting 1-digit LED tables: on Table A (62-24084 boards), 2 Blinks = Pressure Switch Open and 3 Blinks = High Limit Open. On Table B (62-24268 UT boards), 3 Blinks = Pressure Switch Open and 4 Blinks = High Limit Open. 5-Second Ear Test: If your main house blower fan roars nonstop, 3 Blinks is a High Limit fault; if the main blower stays off, clear the brass inducer pressure port.
Dual-Table Disambiguation Chart

Side-by-Side Rheem / Ruud Table A vs. Table B Comparison & Part SKUs

Covers Rheem Criterion II, Classic 80/90 Plus, Prestige (RGRA, RGPJ, RGDG, R92PA, R95PA, R801CA), Ruud Silhouette II / Achiever, and WeatherKing furnaces. Newer 7-segment Ruud/Rheem boards use 2-character codes (10 = Lockout, 22/23 = Pressure Switch, 33 = High Limit, 57 = Flame Rollout).

Blink Count Table A (62-24084 Board) Table B (62-24268 UT Board) Rheem OEM Part SKU & Triage Fix
Steady ON Normal Power / Idle Normal Power / Idle Healthy 24VAC control power. Check thermostat heat call.
1 Blink 1-Hr Ignition Lockout 1-Hr Ignition Lockout Polish 62-23543-01 Flame Sensor or test 62-22868-93 HSI / 62-24141-04 Spark.
2 Blinks Pressure Switch Open Pressure Switch Stuck Closed Ream yellow brass inducer port with paperclip; OEM Switch 42-24196-01 ($38).
3 Blinks High Limit Switch Open Pressure Switch Open Ear Test: Main blower roaring = Limit 47-25349 / Filter; Blower OFF = Brass Port / Trap.
4 Blinks Auxiliary Blower Limit Open Primary High Limit Open Replace dirty air filter immediately; test blower run capacitor µF.
5 Blinks Manual Flame Rollout Open False Flame Sensed CRITICAL: Inspect burner vestibule rollout switches (47-22861-01) & heat exchanger.
6 Blinks Reversed Polarity / Internal Compressor / Rollout Lockout Verify 120V L1/Neutral polarity and cross-check blower door schematic label.