OEM Control Family: Rheem / Ruud 62-24084 (Table A) & 62-24268 (Table B) • WeatherKing
Rheem & Ruud Furnace Blink Code: 3 Blinks Discrepancy Solved
⚡ Instant OEM Answer (Rheem Table A vs. Table B 3-Blink Rule):
Rheem and Ruud use two conflicting 1-digit LED tables: on Table A (62-24084 boards),
2 Blinks = Pressure Switch Open and 3 Blinks = High Limit Open. On Table B (62-24268 UT boards), 3 Blinks = Pressure Switch Open and 4 Blinks = High Limit Open. 5-Second Ear Test: If your main house blower fan roars nonstop, 3 Blinks is a High Limit fault; if the main blower stays off, clear the brass inducer pressure port.
Dual-Table Disambiguation Chart
Side-by-Side Rheem / Ruud Table A vs. Table B Comparison & Part SKUs
Covers Rheem Criterion II, Classic 80/90 Plus, Prestige (RGRA, RGPJ, RGDG, R92PA, R95PA, R801CA), Ruud Silhouette II / Achiever, and WeatherKing furnaces. Newer 7-segment Ruud/Rheem boards use 2-character codes (10 = Lockout, 22/23 = Pressure Switch, 33 = High Limit, 57 = Flame Rollout).
| Blink Count | Table A (62-24084 Board) | Table B (62-24268 UT Board) | Rheem OEM Part SKU & Triage Fix |
|---|---|---|---|
| Steady ON | Normal Power / Idle | Normal Power / Idle | Healthy 24VAC control power. Check thermostat heat call. |
| 1 Blink | 1-Hr Ignition Lockout | 1-Hr Ignition Lockout | Polish 62-23543-01 Flame Sensor or test 62-22868-93 HSI / 62-24141-04 Spark. |
| 2 Blinks | Pressure Switch Open | Pressure Switch Stuck Closed | Ream yellow brass inducer port with paperclip; OEM Switch 42-24196-01 ($38). |
| 3 Blinks | High Limit Switch Open | Pressure Switch Open | Ear Test: Main blower roaring = Limit 47-25349 / Filter; Blower OFF = Brass Port / Trap. |
| 4 Blinks | Auxiliary Blower Limit Open | Primary High Limit Open | Replace dirty air filter immediately; test blower run capacitor µF. |
| 5 Blinks | Manual Flame Rollout Open | False Flame Sensed | CRITICAL: Inspect burner vestibule rollout switches (47-22861-01) & heat exchanger. |
| 6 Blinks | Reversed Polarity / Internal | Compressor / Rollout Lockout | Verify 120V L1/Neutral polarity and cross-check blower door schematic label. |