⚡ Instant OEM Answer (York / Coleman / Luxaire / Evcon LED System): Johnson Controls boards use Green for idle standby, Amber for active flame, and Red Flashes for faults: 3 Red Flashes = Pressure Switch Open; 4 Red Flashes = High Limit Open (escalates to 6 Red Flashes after 3 trips); 5 Red Flashes = Manual Flame Rollout Open; and 7 Red Flashes = 1-Hour Ignition Lockout (clean sensor below 1.5 µA DC or test 40–85 Ω igniter).
Johnson Controls / Source 1 Master Matrix

Complete York, Coleman, Luxaire & Evcon Tri-Color & Red Flash Chart

Covers York Diamond 80/90, Latitude, Affinity (GY8S, GY9S, TG8S, TG9S, TM8X, TM9V), Luxaire Acclimate, and Coleman / Evcon residential & HUD manufactured-home furnaces (DGAA, DGAT, DGAM, MG9S).

LED Color & Count York / Coleman OEM Meaning Source 1 OEM Part SKU Primary Fix & Multimeter Check
Green Steady / Flash Normal Idle Standby / Call S1-33103010000 Zero active faults; Amber heartbeat = normal burner flame established.
Steady Solid Red Internal Control Failure / Hard Fault S1-33103010000 / 50A55 Cycle 120V power; if solid red persists with 24VAC present, replace board.
1 Red Flash Flame Sensed With Gas Valve Off S1-32536835000 Inspect 24V gas valve shutoff seat and dry moisture from board flame terminal.
2 Red Flashes Pressure Switch Stuck Closed S1-02427666001 Drain condensate droplet from silicone hose or replace welded pressure switch.
3 Red Flashes Pressure Switch Stuck Open S1-02427666001 / 024-35271 Flush condensate trap, clear inducer barb, inspect DGAA concentric roof-jack vent.
4 Red Flashes Open High Limit Switch S1-02529041000 Replace clogged air filter immediately; open supply dampers & check capacitor µF.
5 Red Flashes Open Flame Rollout Switch S1-02527747009 CRITICAL: Inspect burner box & heat exchanger before pressing manual rollout pin.
6 Red Flashes 1-Hour High Limit Lockout (3 Trips) S1-02529041000 Escalated from 4 Flashes after 3 consecutive overheat cycles in one heat demand.
7 Red Flashes 1-Hour Ignition Lockout (3 Retries) S1-02537499000 (Sensor)
S1-02532625000 (HSI)
Polish flame sensor rod (≥ 1.5 µA DC) or swap cracked igniter (40–85 Ω cold).
8 / 9 Red Flashes 115V Polarity Reversed / Ground Fault Line L1 / Neutral Verify 120V Hot-to-Ground and < 2.0 VAC Neutral-to-Ground; bond generator neutral.
💡 Coleman / Evcon DGAA & DGAT Mobile Home Booster Motor Note: On sealed-combustion Coleman DGAA and DGAT downflow closet furnaces, a noisy or sluggish upper combustion air booster motor—or a separated inner aluminum exhaust pipe inside the rooftop concentric jack—causes intermittent 3 Red Flashes during windy nights. Also check the washable mesh filter clipped directly inside the louvered front closet door!